Tag Archives: Philippe Plamondon

Canadian research into nanomaterial workplace exposure in the air and on surfaces

An August 30, 2018 news item on Nanowerk announces the report,

The monitoring of air contamination by engineered nanomaterials (ENM) is a complex process with many uncertainties and limitations owing to the presence of particles of nanometric size that are not ENMs, the lack of validated instruments for breathing zone measurements and the many indicators to be considered.

In addition, some organizations, France’s Institut national de recherche et de sécurité (INRS) and Québec’s Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST) among them, stress the need to also sample surfaces for ENM deposits.

In other words, to get a better picture of the risks of worker exposure, we need to fine-tune the existing methods of sampling and characterizing ENMs and develop new one. Accordingly, the main goal of this project was to develop innovative methodological approaches for detailed qualitative as well as quantitative characterization of workplace exposure to ENMs.

A PDF of the 88-page report is available in English or in French.

An August 30, 2018 (?) abstract of the IRSST report titled An Assessment of Methods of Sampling and Characterizing Engineered Nanomaterials in the Air and on Surfaces in the Workplace (2nd edition) by Maximilien Debia, Gilles L’Espérance, Cyril Catto, Philippe Plamondon, André Dufresne, Claude Ostiguy, which originated the news item, outlines what you can expect from the report,

This research project has two complementary parts: a laboratory investigation and a fieldwork component. The laboratory investigation involved generating titanium dioxide (TiO2) nanoparticles under controlled laboratory conditions and studying different sampling and analysis devices. The fieldwork comprised a series of nine interventions adapted to different workplaces and designed to test a variety of sampling devices and analytical procedures and to measure ENM exposure levels among Québec workers.

The methods for characterizing aerosols and surface deposits that were investigated include: i) measurement by direct-reading instruments (DRI), such as condensation particle counters (CPC), optical particle counters (OPC), laser photometers, aerodynamic diameter spectrometers and electric mobility spectrometer; ii) transmission electron microscopy (TEM) or scanning transmission electron microscopy (STEM) with a variety of sampling devices, including the Mini Particle Sampler® (MPS); iii) measurement of elemental carbon (EC); iv) inductively coupled plasma mass spectrometry (ICP-MS) and (v) Raman spectroscopy.

The workplace investigations covered a variety of industries (e.g., electronics, manufacturing, printing, construction, energy, research and development) and included producers as well as users or integrators of ENMs. In the workplaces investigated, we found nanometals or metal oxides (TiO2, SiO2, zinc oxides, lithium iron phosphate, titanate, copper oxides), nanoclays, nanocellulose and carbonaceous materials, including carbon nanofibers (CNF) and carbon nanotubes (CNT)—single-walled (SWCNT) as well as multiwalled (MWCNT).

The project helped to advance our knowledge of workplace assessments of ENMs by documenting specific tasks and industrial processes (e.g., printing and varnishing) as well as certain as yet little investigated ENMs (nanocellulose, for example).

Based on our investigations, we propose a strategy for more accurate assessment of ENM exposure using methods that require a minimum of preanalytical handling. The recommended strategy is a systematic two-step assessment of workplaces that produce and use ENMs. The first step involves testing with different DRIs (such as a CPC and a laser photometer) as well as sample collection and subsequent microscopic analysis (MPS + TEM/STEM) to clearly identify the work tasks that generate ENMs. The second step, once work exposure is confirmed, is specific quantification of the ENMs detected. The following findings are particularly helpful for detailed characterization of ENM exposure:

  1. The first conclusive tests of a technique using ICP-MS to quantify the metal oxide content of samples collected in the workplace
  2. The possibility of combining different sampling methods recommended by the National Institute for Occupational Safety and Health (NIOSH) to measure elemental carbon as an indicator of NTC/NFC, as well as demonstration of the limitation of this method stemming from observed interference with the black carbon particles required to synthesis carbon materials (for example, Raman spectroscopy showed that less than 6% of the particles deposited on the electron microscopy grid at one site were SWCNTs)
  3. The clear advantages of using an MPS (instead of the standard 37-mm cassettes used as sampling media for electron microscopy), which allows quantification of materials
  4. The major impact of sampling time: a long sampling time overloads electron microscopy grids and can lead to overestimation of average particle agglomerate size and underestimation of particle concentrations
  5. The feasibility and utility of surface sampling, either with sampling pumps or passively by diffusion onto the electron microscopy grids, to assess ENM dispersion in the workplace

These original findings suggest promising avenues for assessing ENM exposure, while also showing their limitations. Improvements to our sampling and analysis methods give us a better understanding of ENM exposure and help in adapting and implementing control measures that can minimize occupational exposure.

You can download the full report in either or both English and French from the ‘Nanomaterials – A Guide to Good Practices Facilitating Risk Management in the Workplace, 2nd Edition‘ webpage.

Gloves, Québec’s (Canada) Institut de recherche Robert-Sauvé en santé et en sécurité du travail, and a workplace nanotoxicity methodology report

A new report on a workplace health and safety issue in regard to nanoparticles (Development of a Method of Measuring Nanoparticle Penetration through Protective Glove Materials under Conditions Simulating Workplace Use)  was released in June 2013 by Québec’s Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST). Little research has been done on exposure through skin (cutaneous exposure), most research has focused on exposure by inhalation according to the report (en français version here),

In the workplace, the main pathway to NP exposure is inhalation (Ostiguy et al., 2008a). Exposure by the cutaneous route has not been studied much, partly because of the widely held belief that skin offers an impermeable barrier to NPs (Truchon et al., 2008). Yet a growing number of studies have pointed to the possible percutaneous absorption of NPs, such as in the case of skin damaged by abrasion (Zhang et al., 2008), repeated flexion (Rouse et al., 2007) or even through intact skin (Ryman-Rasmussen et al., 2006). Pores, hair follicles and sweat glands may also play a role in facilitating absorption of NPs through the skin (Hervé-Bazin, 2007). The nanoparticles are then carried throughout the body by the lymphatic circulatory system (Papp et al., 2008). Induced direct toxic effects have also been reported for epidermal keratinocyte cells exposed to carbon nanotubes and other types of NPs (Shvedova, 2003). [p. 17 PDF version; p. 1 print version; Note: See report bibliography for citations]

The researchers examined gloves made of four different types of material: nitrile, latex, neoprene, and butyl rubber under a number of different conditions. One type of nanoparticle was used for the study, titanium dioxide in powder and liquid forms. The report summary provides a bit more detail about the decision to develop a methodology and the testing methods,

With the exponential growth in industrial applications of nanotechnologies and the increased risk of occupational exposure to nanomaterials, the precautionary principle has been recommended. To apply this principle, and even though personal protective equipment against nanoparticles must be considered only as a last resort in the risk control strategy, this equipment must be available. To respond to the current lack of tools and knowledge in this area, a method was developed for measuring the penetration of nanoparticles through protective glove materials under conditions simulating workplace use.

This method consists of an experimental device for exposing glove samples to nanoparticles in powder form or in colloidal solution, while at the same time subjecting them to static or dynamic mechanical stresses and conditions simulating the microclimate in the gloves. This device is connected to a data control and acquisition system. To complete the method, a sampling protocol was developed and a series of nanoparticle detection techniques was selected.

Preliminary tests were performed using this method to measure the resistance of four models of protective gloves of different thicknesses made of nitrile, latex, neoprene and butyl to the passage of commercial TiO2 nanoparticles in powder form or colloidal solution. The results seem to indicate possible penetration of the nanoparticles in some types of gloves, particularly when subjected to repeated mechanical deformation and when the nanoparticles are in the form of colloidal solutions. Additional work is necessary to confirm these results, and consideration should be given to the selection of the configurations and values of the parameters that best simulate the different possible workplace situations. Nevertheless, a recommendation can already be issued regarding the need for regular replacement of gloves that have been worn, particularly with the thinnest gloves and when there has been exposure to nanoparticles in colloidal solution.

For interested parties, here’s a citation for and a link to the report (PDF),

Development of a Method of Measuring Nanoparticle Penetration through Protective Glove Materials under Conditions Simulating Workplace Use by Dolez, Patricia; Vinches, Ludwig; Perron, Gérald; Vu-Khanh, Toan; Plamondon, Philippe; L’Espérance, Gilles; Wilkinson, Kevin; Cloutier, Yves; Dion, Chantal; Truchon, Ginette
Studies and Research Projects / Report  R-785, Montréal, IRSST, 2013, 124 pages.

I last wrote about gloves and toxicity in a June 11, 2013 posting about gloves with sensors (they turned blue when exposed to toxic levels of chemicals). It would be interesting if they could find a way to create gloves with sensors that warn you when you are reaching dangerous levels of exposure through your gloves. Of course, first they’d have to determine what constitute a dangerous level of exposure. The US National Institute of Occupational Health and Safety (NIOSH) recently released its recommendations for exposure to carbon nanofibers and carbon nanotubes (my April 26, 2013 posting). In layperson’s terms, the recommended exposure is close to zero exposure. Presumably, the decision was based on the principle of being ‘safe rather than sorry’.

One final comment about exposure to engineered nanoparticles through skin, to date there has been no proof that there has been any significant exposure via skin. In fact, the first significant breach of the skin barrier was achieved for medical research, Chad Mirkin and his team at Northwestern University trumpeted their research breakthrough (pun intended) last year, from my July 4, 2012 posting,

Researchers at Northwestern University (Illinois, US) have found a way to deliver gene regulation technology using skin moisturizers. From the July 3, 2012 news item on Science Blog,

A team led by a physician-scientist and a chemist — from the fields of dermatology and nanotechnology — is the first to demonstrate the use of commercial moisturizers to deliver gene regulation technology that has great potential for life-saving therapies for skin cancers.

The topical delivery of gene regulation technology to cells deep in the skin is extremely difficult because of the formidable defenses skin provides for the body. The Northwestern approach takes advantage of drugs consisting of novel spherical arrangements of nucleic acids. These structures, each about 1,000 times smaller than the diameter of a human hair, have the unique ability to recruit and bind to natural proteins that allow them to traverse the skin and enter cells.

This goes a long way to explaining why primary occupational health and safety research has focused on exposure via inhalation rather than skin.  That said, I think ensuring safety means minimizing exposure by all routes until more is known about the hazards.