Tag Archives: Thomas Theis

Molecular ‘lightbulb’ could mean new form of magnetic resonance imaging (MRI)

A new technique promises to show body chemistry in action according to a March 25, 2016 news item on phys.org,

Duke University researchers have taken a major step towards realizing a new form of MRI that could record biochemical reactions in the body as they happen.

In the March 25 issue of Science Advances, they report the discovery of a new class of molecular tags that enhance MRI signals by 10,000-fold and generate detectable signals that last over an hour. The tags are biocompatible and inexpensive to produce, paving the way for widespread use of magnetic resonance imaging (MRI) to monitor metabolic processes of conditions like cancer and heart disease in real time.

“This represents a completely new class of molecules that doesn’t look anything at all like what people thought could be made into MRI tags,” said Warren S. Warren, James B. Duke Professor and Chair of Physics at Duke, and senior author on the study. “We envision it could provide a whole new way to use MRI to learn about the biochemistry of disease.”

A March 25, 2016 Duke University news release (also on EurekAlert), which originated the news item, offers more information about the new technique,

MRI takes advantage of a property called spin, which makes the nuclei in hydrogen atoms act like tiny magnets. Applying a strong magnetic field, followed by a series of radio waves, induces these hydrogen magnets to broadcast their locations. Since most of the hydrogen atoms in the body are bound up in water, the technique is used in clinical settings to create detailed images of soft tissues like organs, blood vessels and tumors inside the body.

But the technique also has the potential to show body chemistry in action, said Thomas Theis, assistant research professor of chemistry at Duke and co-lead author on the paper. “With magnetic resonance in general, you have this unique sensitivity to chemical transformations. You can see them and track them in real time,” Theis said.

MRI’s ability to track chemical transformations in the body has been limited by the low sensitivity of the technique, which makes small numbers of molecules impossible to detect without using unattainably massive magnetic fields.

For the past decade, researchers have been developing methods to “hyperpolarize” biologically important molecules, converting them into what Warren calls magnetic resonance “lightbulbs.”

With this boosted signal, these “lightbulbs” can be detected even in low numbers. “Hyperpolarization gives them 10,000 times more signal than they would normally have if they had just been magnetized in an ordinary magnetic field,” Warren said.

While promising, Warren says these hyperpolarization techniques face two fundamental problems: incredibly expensive equipment — around 3 million dollars for one machine — and most of these molecular lightbulbs burn out in a matter of seconds.

“It’s hard to take an image with an agent that is only visible for seconds, and there are a lot of biological processes you could never hope to see,” said Warren. “We wanted to try to figure out what molecules could give extremely long-lived signals so that you could look at slower processes.”

Jerry Ortiz Jr., a graduate student at Duke and co-lead author on the paper, synthesized a series of molecules containing diazarines, a chemical structure which is composed of two nitrogen atoms bound together in a ring. Diazirines were a promising target for screening because their geometry traps hyperpolarization in a “hidden state” where it cannot relax quickly.

Using a simple and inexpensive approach to hyperpolarization called SABRE-SHEATH, in which the molecular tags are mixed with a spin-polarized form of hydrogen and a catalyst, the researchers were able to rapidly hyperpolarize one of the diazirine-containing molecules, greatly enhancing its magnetic resonance signals for over an hour.

Qiu Wang, assistant professor of chemistry at Duke and co-author on the paper, said this structure is a particularly exciting target for hyperpolarization because it has already been demonstrated as a tag for other types of biomedical imaging.

“It can be tagged on small molecules, macro molecules, amino acids, without changing the intrinsic properties of the original compound,” said Wang. “We are really interested to see if it would be possible to use it as a general imaging tag.”

The scientists believe their SABRE-SHEATH catalyst could be used to hyperpolarize a wide variety of chemical structures at a fraction of the cost of other methods.

“You could envision, in five or ten years, you’ve got the container with the catalyst, you’ve got the bulb with the hydrogen gas. In a minute, you’ve made the hyperpolarized agent, and on the fly you could actually take an image,” Warren said. “That is something that is simply inconceivable by any other method.”

The researchers have provided an artistic representation of the molecular ‘lightbulbs’,

Caption: Duke scientists have discovered a new class of inexpensive and long-lived molecular tags that enhance MRI signals by 10,000-fold. To activate the tags, the researchers mix them with a newly developed catalyst (center) and a special form of hydrogen (gray), converting them into long-lived magnetic resonance 'lightbulbs' that might be used to track disease metabolism in real time. Credit: Thomas Theis, Duke University

Caption: Duke scientists have discovered a new class of inexpensive and long-lived molecular tags that enhance MRI signals by 10,000-fold. To activate the tags, the researchers mix them with a newly developed catalyst (center) and a special form of hydrogen (gray), converting them into long-lived magnetic resonance ‘lightbulbs’ that might be used to track disease metabolism in real time. Credit: Thomas Theis, Duke University

Here’s a link to and a citation for the paper,

Direct and cost-efficient hyperpolarization of long-lived nuclear spin states on universal 15N2-diazirine molecular tags by Thomas Theis, Gerardo X. Ortiz Jr, Angus W. J. Logan, Kevin E. Claytor, Yesu Feng, William P. Huhn, Volker Blum, Steven J. Malcolmson, Eduard Y. Chekmenev, Qiu Wang, and Warren S. Warren. Science Advances  25 Mar 2016: Vol. 2, no. 3, e1501438 DOI: 10.1126/sciadv.1501438

This paper appears to be open access.

Webcast of US NSF workshop for a future nanotechnology infrastructure support program

The US National Science Foundation (NSF) will be webcasting some of the Workshop for a Future Nanotechnology Infrastructure Support Program (Aug. 18 – 19, 2014) sessions live. From the NSF workshop notice (Note: Some links have been removed),

August 18, 2014 8:00 AM  to
August 18, 2014 12:00 PM
Arlington

August 19, 2014 8:00 AM  to
August 19, 2014 12:00 PM
Arlington

To broaden engagement, portions of the Workshop for a Future Nanotechnology Infrastructure Support Program will be webcast. (The approximate webcast times shown above are Eastern Daylight Time.)

The workshop will convene a panel of experts from academe, industry, and government to:

develop a vision of how a future nanotechnology infrastructure support program could be structured, and
determine the key needs for the broad user communities over the coming decade.

The workshop is a next step in NSF’s preparation for developing a program to succeed the National Nanotechnology Infrastructure Network (NNIN), after having received community input in response to a recent Dear Colleague Letter (DCL 14-068).

The workshop is co-chaired by Dr. Thomas Theis (IBM Research, on assignment to the Semiconductor Research Corporation) and Dr. Mark Tuominen (University of Massachusetts, Amherst).

The final agenda will be available on this page soon. Morning sessions of the workshop will be broadcast via WebEx; afternoon breakout sessions will not be broadcast.

If you have never used WebEx before or if you want to test your computer’s compatibility with WebEx, please go to http://www.webex.com/lp/jointest/, enter the session information and click “Join”. Please feel free to contact WebEx Support if you are having trouble joining the test meeting.

Session number: 643 345 106
Session password: This session does not require a password.

The notice goes on to offer specific instructions for joining the session online or by phone.

You can view the NSF’s Dear Colleague letter here and/or go here to find the previous infrastructure program (National Nanotechnology Infrastructure Network [NNIN]), which ended Feb. 28, 2014.